Surplus electrical wire & cable buyers · New York State

Direct buyer review · no fee to submit a lot

Call or text 614-715-3047

saleselectricalbuyers@gmail.com

New York Wire Buyers Surplus wire & cable desk

TC and TC-ER multi-conductor cable

Tray cable buyers in New York

Tray cable is what a plant runs when it wants to stop pulling conduit. Conductor count, voltage class and shielding decide what a reel is worth, and the ER rating decides who can use it.

600 V to 2 kV14 AWG to 1000 kcmilShielded and unshielded
Cable reels of several colors standing on gravel in an outdoor storage area

Sell this cable

Send the construction, size and footage. Photographs can follow.

No fee and no obligation. Nothing is bought, moved or scheduled until written lot terms are agreed.

Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com

Quick answer

Tray cable is a factory assembly of two or more insulated conductors under a jacket, listed to UL 1277 and covered by NEC Article 336. It runs from 600 V to 2 kV, from 14 AWG to 1000 kcmil, with two to several dozen conductors. TC-ER adds the exposed-run rating. Value is driven by conductor count and size, voltage class, shielding and jacket type, then by length and water damage.

What separates tray cable from a bundle of wire

Tray cable is a listed assembly, not a group of conductors pulled together on site. The conductors are laid up with fillers, wrapped and jacketed in a single operation, and the resulting cable carries a UL 1277 listing that permits it to be installed in cable tray without a raceway. That listing is the product. It is what allows a plant to run a multi-conductor cable across a hundred feet of tray, drop it down a column and land it in a junction box without installing conduit for any of it.

The construction also explains the failure modes. Fillers are there to keep the assembly round, and they are also the path water takes through the cable if the jacket is breached. The jacket is the only mechanical protection, so a nick from a tray edge or a crush from a reel that was dropped is more serious than the same damage on armoured cable. And because the conductors are close together for their whole length, a cable with damaged insulation usually fails at a specific point rather than gradually.

Cable reels of several colors standing on gravel in an outdoor storage area

Conductor count, voltage class and shielding

Three things move the price before length is even discussed. The first is conductor count and size together: 12 AWG 3/C is a commodity, 12 AWG 12/C is a different asset, and 1/0 4/C is a heavy feeder that happens to be in tray form. The second is voltage class. A 600 V cable and a 2 kV cable can look almost identical from the outside, and the 2 kV version serves a smaller market at a higher price.

The third is shielding, which is where tray cable becomes a specialist item. An overall aluminum foil with a drain wire is standard for variable-frequency drive cable and for anything in an electrically noisy plant. Braid shields cost more and handle flexing better. Individually shielded pairs are instrumentation constructions and are priced on pair count rather than conductor count. A reel with a shield is worth more than the same copper unshielded, provided the shield is intact and the drain wire is still attached.

ConstructionTypical New York useWhat drives the price
14 AWG 3/C TCControl and signal runsCopper weight, remaining length
12 AWG 4/C TCSmall motor and control dropsVolume, jacket condition
10 AWG 7/C TCMulti-function equipment connectionsConductor count
8 AWG 4/C TC-ERExposed runs to packaged equipmentER rating and gauge
1/0 4/C TCFeeder to a machine or panelSize, footage, reel quality
500 kcmil 3/C TCHeavy industrial feederCopper or aluminum, footage
Shielded VFD cableDrive to motor connectionsShield integrity and pair count
2 kV TCHigher-voltage plant distributionVoltage class, small buyer pool

Water, fillers and the jacket

Tray cable that has been stored outdoors with the ends open is a different product from the same cable stored indoors. The fillers act as a wick, and water travels a surprising distance into a reel along them. Once the interior is wet, the cable may still test sound but it cannot be sold as new stock, and a buyer who has been caught once will ask about storage before asking about price.

Jacket condition is the second question. PVC jackets harden and crack under UV, CPE holds up better, and low-smoke zero-halogen jackets are softer and mark easily but are required in tunnels and some occupied spaces. A cable that has been dragged out of a tray and coiled on a plant floor will have abrasion on one side along its whole length, and that abrasion is where a fault will eventually start. Reels stored on edge, off the ground and under cover are worth materially more than the same cable in a heap.

  • The reel tag, showing voltage class, conductor count, size and footage
  • The jacket print, which repeats the same information
  • A cut end showing conductor count, color code and any shield
  • The shield and drain wire, photographed where the jacket is stripped back
  • The jacket surface, showing abrasion, UV cracking or crush marks

Specification

What a buyer needs to know about this cable

Every row below changes what a lot is worth. If the reel tag is gone, the jacket print and a cut end usually answer most of it.

Missing detail is not a problem — say what is missing and the review works from photographs.

Specification checklist
StandardUL 1277; NEC Article 336
Voltage classes600 V, 1 kV and 2 kV
Size range14 AWG through 1000 kcmil
Conductor countTwo conductors up to several dozen; 3, 4, 7 and 12 are the common plant configurations
ConductorsCopper, normally stranded; Class B stranding in the larger sizes
ShieldingUnshielded, overall foil with a drain wire, braid, or individually shielded pairs
JacketsPVC, chlorinated polyethylene (CPE), or a low-smoke zero-halogen compound
Exposed-run ratingTC-ER, which permits an exposed run between a tray and equipment without conduit

Constructions

Tray cable lots we review

Plant surplus is usually well documented and badly stored, which makes the photographs more useful than the paperwork.

01

Tagged TC-ER reels

Whole or part reels with the ER rating printed and the tag intact. The most saleable category, because the exposed-run rating widens the buyer pool.

02

Shielded drive cable

VFD cable with an overall foil or braid shield. Priced on shield construction, conductor count and length, and in demand wherever drives are being replaced.

03

Multi-conductor control cable

7/C, 12/C and 19/C constructions in 14 and 12 AWG. Value is in the conductor count, so a count at the cut end is the key photograph.

04

Large feeder TC

1/0 to 500 kcmil in 3/C and 4/C. Heavy, often aluminum, and worth a proper review when the footage is known.

05

Weathered or water-damaged reels

Jacket cracked, ends open, fillers wet. Recovery material, and worth handling only alongside other cable.

New York

Tray cable in the New York market

Tray cable is an industrial and institutional product, and New York's industrial map explains where it comes from. Chemical and paper plants along the Niagara and upper Hudson corridors, food and dairy processing in the Finger Lakes and Central New York, water and wastewater treatment everywhere, and the semiconductor and laboratory construction in the Capital Region all run tray. When a line is rebuilt or a drive is replaced, the cable that comes out is tray cable.

The other source is new construction over-order. Tray cable is bought by the reel for a specific equipment package, and when the package changes the reel is left. Those reels are usually tagged, often shielded, and frequently still banded, which makes them the best thing in the family. The worst is the plant floor sweepings: short lengths cut at every junction box, jacket abraded, no identification.

What helps a New York lot move

  • Voltage class, conductor count and size, as printed
  • Whether it is TC or TC-ER, and whether the print says so
  • Shield construction, if there is one, and whether the drain wire is intact
  • Footage, reel condition, and whether the ends were sealed
  • Copper or aluminum conductors, and the jacket compound if it is marked
Narrow warehouse aisle lined with cable reels on a concrete floor
Tray cable is sold on construction, not on weight. A photograph of the cut end answers the conductor-count question faster than any description.

Seller questions

Questions sellers ask

What is the difference between TC and TC-ER?

TC-ER carries an exposed-run rating, which allows the cable to run outside a raceway between a tray and the equipment it serves. Plain TC is intended for tray, raceway or enclosed spaces. The ER rating is printed on the jacket and it materially widens the number of buyers who can use a reel.

How does conductor count affect the price?

Directly, because more conductors means more copper and a more specialised product. A 12 AWG 3/C cable is a commodity that many buyers can use; a 12 AWG 12/C cable serves a much narrower set of applications but carries far more copper per foot. Pricing has to account for both the metal and the market.

Can tray cable be direct buried?

Only where the cable itself carries a direct-burial marking, and most tray cable does not. Tray cable is designed for tray, raceway and, in the ER version, exposed runs. Burying an unmarked reel is a mistake that shows up as a failed inspection or a cable failure years later.

What does a shield add to the value?

A shield turns a general-purpose cable into a specific one. Foil-and-drain shielding is what drive and instrumentation applications require, so a shielded reel can serve a buyer who cannot use the unshielded version. The premium depends on the shield type, the pair count and whether the drain wire and foil are intact.

Why does water damage matter so much in tray cable?

Because the fillers wick water along the length of the cable, not just at the end. A reel stored with open ends in a wet yard can have moisture deep inside the assembly, which disqualifies it from being sold as new stock and often from reuse in a critical application. Sealed ends and indoor storage are the protection.

Next step

Send the lot details

Include the storage city, how it is stored and what can reach it. If you have photographs of reel tags or jacket print, send them with the enquiry.

Send the lot details

Call or text the buying desk: 614-715-3047

saleselectricalbuyers@gmail.com

Send the lot

One desk reviews every lot that arrives.

No fee and no obligation. Nothing is bought, moved or scheduled until written lot terms are agreed.

Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com

Call 614-715-3047 Get a buy quote