Copper and aluminum are easy to separate with a knife and a pair of scales, and surprisingly easy to confuse on a reel that has been painted, tinned, weathered or mislabelled. The difference is roughly three to one by weight, and it decides most of what a cable lot is worth.
Sell your wire
The guide explains the terms. The quote is the answer for your lot.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com

Look at a freshly cut end: copper is salmon red and aluminum is silver white, though tinned copper and copper-clad aluminum both read silver until you look closely. Weight settles it — copper is about 3.3 times denser, so the same size feels unmistakably heavier. A magnet proves only the presence of steel, never the absence of aluminum.
Start at the cut end
Everything else is inference; a cut end is evidence. Cut a few inches off with a proper cable knife or a fine-tooth saw, square it up, and look at it in daylight. Copper is a warm red-brown, dulling to a darker brown as it oxidises. Aluminum is a cool silver-gray that goes chalky white with oxide. Stranded conductors show the color on every strand, which is a useful check against a painted or sleeved outer surface.
Tinned copper is the common trap. A tin coating makes a copper conductor look silver, and on an old cable the coating may be patchy, with copper showing through where the strands rub. Scrape a strand with a knife blade: tin comes away as a thin bright layer over red metal, aluminum stays silver all the way through. Copper-clad aluminum is the reverse trap — it looks convincingly copper on the outside and shows a white core when cut, which is why the cut, not the surface, is the test.
If the end has been sealed with a heat-shrink cap or a putty compound, cut behind the seal only on cable you are certain is dead and released. That certainty belongs to the owner's qualified crew, not to a seller with a knife, and the safety guide on this site explains why the two questions are not the same.
Color, weight and the magnet
The three quick tests answer different questions, and it is worth knowing which one you are actually asking.
- A magnet sticking to a conductor means steel core or steel armour, not aluminum.
- A magnet sliding off tells you only that no steel is present.
- Weighing a known length is the only field test that quantifies the metal.
- When two tests disagree, trust the cut end.
| Test | What it shows | What it cannot show |
|---|---|---|
| Color at a fresh cut | Red metal or silver metal, and whether a silver surface is a coating | Nothing if the end is sealed, corroded or painted |
| Weight in the hand, or on a scale | Copper is roughly 3.3 times denser, so a copper length of a given size is far heavier | The difference between copper and a heavy steel-cored conductor without a size reference |
| Magnet | The presence of steel — armour, steel core, steel conduit or a steel reel | Anything about the conductor, since neither copper nor aluminum is magnetic |
| Printed legend | The metal as the manufacturer declared it, with size and standard | Whether the reel still holds the cable the legend describes |
| Sparks from a grinder | Nothing useful, and it damages the material | Not a recognised field test — do not do it |
Where each metal turns up
Copper dominates anything where current density, termination reliability or a small cross-section matters. Medium-voltage and high-voltage underground cable in New York is very often copper, particularly in the dense downstate network where ducts are full and conductor sizes are pushed hard. Building wire, control cable, motor leads, grounding conductors, fire alarm and instrumentation are copper almost without exception. Copper is also the default for anything that will be spliced in a wet location, because the metal tolerates it better.
Aluminum dominates where weight and cost per amp matter more than size: overhead conductors of every kind, large feeder and service entrance cable, utility service laterals, and the big 600 V feeders in industrial plants. Aluminum is entirely serviceable in those roles when it is installed with the right connectors and the right inhibitor. What it does not tolerate is improvisation — a mismatch between conductor and lug is where most aluminum failures begin.
The practical consequence for a seller is that a lot's copper content is usually concentrated in a minority of the reels. A yard full of large aluminum feeder and a handful of copper control and medium-voltage reels will carry most of its value in the small pile. Sorting by metal before a buyer arrives is the single most effective thing a seller can do, and it costs a knife and an afternoon.
Termination and the bimetal problem
Aluminum forms an oxide layer within seconds of being exposed to air, and that layer is an insulator. Terminations therefore depend on abrading the surface, applying an oxide-inhibiting compound, and using a connector listed for the metal — the AL7 and CU9 markings on a lug exist for this reason. Copper does not need the same ceremony, although it also benefits from a clean surface and a correctly torqued connection.
The harder issue is where the two metals meet. Copper and aluminum in contact, with moisture present, form a galvanic couple: the aluminum becomes the anode, corrodes, and the joint heats. Bimetal connectors and transition splices exist precisely to separate the metals, and twisting a copper conductor onto an aluminum one is not an acceptable substitute. Aluminum also creeps under sustained compression and expands more with temperature, so a termination that was tight when made can loosen over years of load cycling — which is why aluminum terminations are inspected and re-torqued, and why a seller's honest note that a cable came out of a failed joint is useful information.
For valuation, this mostly matters as a source of doubt. Cable cut out of service with a scorched lug, a melted splice body or a heat-discolored conductor end has a history, and that history is visible. Photograph it and say what it is, rather than cutting the damaged section away and hoping nobody notices that the length has shrunk.
Why copper content is a floor, not a price
A copper conductor has a value that can be realised by melting it, minus the cost of getting it to a furnace and the loss in the process. That is the floor, and it is remarkably reliable: it does not care about the voltage class, the insulation type, the standard, or whether the reel tag survived. It is the number a buyer can defend without knowing anything else about the lot.
The actual price is set by what the cable can still do as cable, which is usually more than the metal is worth. Reuse value depends on identity, footage, condition and documentation — the four things that turn a heavy object into a specified product. So copper content tells you the worst case and almost never the offer. Sellers who lead with the metal weight are negotiating on the floor, and should not be surprised when the offer sits near it.
Aluminum has no comparable floor in the same sense: the metal is worth far less per pound, so a lot of unidentified aluminum cable is priced on handling and freight, and a distant yard can be worth nothing at all. That asymmetry is why a mixed pallet of copper and aluminum is worth more separated than together, even though the combined weight is unchanged.
Guide questions
Questions about this
Will a magnet tell me whether cable is copper or aluminum?
No. Neither metal is magnetic, so a magnet that does not stick has told you nothing about the conductor. A magnet that does stick has found steel — a steel core in overhead conductor, steel wire armour, or a steel reel — which is useful information but a different question.
Is tinned copper worth less than bright copper?
Not meaningfully. The tin coating is thin and the copper underneath is the same copper. Tinned conductor is common in marine, industrial and older rubber-insulated cable, and it is bought on the same basis as bare copper once the construction has been identified.
Can aluminum cable be sold as cable rather than scrap?
Yes, particularly large feeder and service cable with a legible legend and a known length, because it has a genuine reuse market in plants and at utilities. Unidentified aluminum, or aluminum with damaged ends and no footage, usually ends up priced on handling cost rather than metal value.
Keep reading
Related reading
- Aluminum wire buyersWhere large aluminum feeder and service cable goes
- Copper wire buyersThe other side of the same question
- Bare copper wire buyersGrounding and bare conductor, priced on metal
- ACSR vs AAAC conductorThe overhead versions of the same choice
- How a cable lot is valuedWhy the metal number is a floor rather than an offer
Next step
Ready to send the lot?
The guide is the background. The lot review is the answer — send the details and a buyer will respond.
Send the lot
Six details are enough to start a review. Photographs of reel tags and jacket print can follow by email or text.
Prefer to talk? 614-715-3047 · saleselectricalbuyers@gmail.com